Alternating Current (AC) Solenoids

March 5, 2009 | tags solenoid  AC Solenoid   | views

Unlike DC solenoids, AC solenoids provide relatively high operating/cycling frequencies and low cycling times; this results in hard operation which influences service life. Power consumption depends on the position of the plunger.

High cycling frequencies can cause dangerously high thermal loading in AC solenoids and the maximum permissible temperature is therefore the limiting factor for cycling frequency.