Varying the current applied makes it possible to use a smaller solenoid. To prevent the winding from overheating the current is limited by a resistor after the plunger reaches the end of the stroke. This circuit cannot be used with high operating frequencies. The size of the dropping resistor depends on the resistance of the winding.
...
There are three ways of damping solenoids:
12.1. Damping by Ohmic resistance
A parallel resistor can be used to limit the voltage surge that occurs when the power to the solenoid is cut off. As a result, however, the drop-out time increases as does the power requirement. Both are reduced as the parallel resistance is reduced.
Suitable circuitry will influence the operating times and service life of the solenoid. In an AC circuit the over-voltage at cut-off is fully damped however this severely delays the drop-out time. In
Protection can be divided into three classes:
If solenoids are to operate reliably, they must be provided with suitable power; the following are a few terms to aid in understanding:
9.1 Nominal voltage
The nominal voltage is that with which a solenoid is normally operated, the tolerance is +5% to -9%.
When selecting a suitable solenoid, temperature must be considered.
8.1. Ambient temperature
The ambient temperature is the temperature (°C) surrounding the solenoid when it is operating. If the range is outside +40°C to -50°C design changes may be required.
The use of solenoids necessitates a certain chronological sequence best clarified with the following terms:
7.1. Power-off pause
The power-off pause (in seconds) is the time between switching off the current and switching it on again.
A solenoid is a device designed to convert electrical energy into linear work: this can be either push or pull.